Platinum RTD Sensor - PT1000 - 3 Wire 1 meter long

Platinum RTD Sensor - PT1000 - 3 Wire 1 meter long — Adafruit — 3984

PT1000 platinum RTD probe on a 1 m three-wire cable, 1000 Ω at 0°C. Requires a dedicated amplifier (e.g. MAX31865) to convert resistance to temperature; not directly readable by a standard ADC.

Pinout

Logical pinout · physical placement not verified
PLATINUM RTD SENSOR - RTD lead A3-wire compensation leadRTD lead B
  • RTD lead A

    One side of the PT1000 platinum resistor. Adafruit states two wires connect to either side of the platinum resistor.

    Type · Unknown
  • RTD lead B

    Other side of the PT1000 platinum resistor. Adafruit states two wires connect to either side of the platinum resistor.

    Type · Unknown
  • 3-wire compensation lead

    Third RTD wire connected to one end of the PT1000 for 3-wire RTD amplifier lead-resistance compensation. Leave disconnected for 2-wire amplifiers per Adafruit.

    Type · Unknown

Start wiring

I2C · SPI · Single data line · 3.3 – 5 V · Breakout

Some modules need I2C or signal pull-ups — check the datasheet.

Temp & humidity

165 other options

DHT/AHT sensors, SHT-series humidity chips, BMP and LPS barometers, BME combined sensors, DS18B20 probes, thermocouple amplifiers and non-contact MLX IR sensors — about 165 listings, very different accuracy classes.

View all 165

Related groups

4 groups